Turbine vents are not low profile but in windy climates they provide more ventilation than other types of roof vents.
Low sloped roof ventilation.
I don t know what the minimum slopes allowed for your type of metal roof materials are.
You need to create an unvented roof assembly.
If your low roof that ends at a wall high side is a pitched roof say 4 12.
I m trying to vent a 1 12 roof that has not been vented.
Smartvent can be modified to provide intake ventilation for new roofs or re roofs through the fascia board for low slope roof with less than a 4 12 pitch.
For over generations multi residential flats buildings were constructed in north american with low slope roofs.
So that probably means you are going to use a modified bitumen roof or something like that for the 5 12 low slope flat roofs.
The roof design included an interstial space of 1 5 to 2 meters between the ceiling and roof deck.
I m a flat low slope roofer.
Where wood shingles or shakes are used a minimum 1 4 inch 6 mm vented air space separates the shingles or shakes and the roofing underlayment above the structural sheathing.
Ventilate at the gable ends and insulate the ceilings of the space if not vaulted.
So it is essentially boxed in on 3 sides.
You need to make sure that you have an air space of at least 6 inches between the top of your insulation layer and.
To properly ventilate a low slope roof we ve created a special assembly method which allows the installation of ridge vent and eliminates associated roof leaks.
Hi all in new.
An airspace is left above the ceiling insulation and below the under side of the roof decking and the roof is vented either around its perimeter with soffit vents a flat roof or the roof may be include intake venting at its lower edge through a soffit and outlet venting through a half ridge vent or similar outlet vent along the roof s uppermost edge a low sloped roof.
The downside to turbine vents is that they don t provide much venting power on calm days.
On a windy day the vent s turbine mechanism spins which moves hot attic air up and out.
November 19 2014 9 08pm 1.
The top of the roof meets the wall of the house and the 2 sides also meet walls.
Check the specs for the exact minimum.
In climate zones 5 6 7 and 8 any air.
This attic space was typically vented via static air vents.
About 12 x 18.
We raised a ridge vent by 2 inches from the roof surface.
One of my goals this year is to learn about ventilation for my customers so we can make good recommendations for them.
This clearance is more than sufficient to prevent any water from entering your house through the ridge vent.